+86 18126862446
News

Activity
Notice
Industry

Types of Ultrasound Probes: Convex vs Linear vs Phased Array

2026-10-14
51
Guangzhou Sonostar Technologies Co., Limited

Before price, brand, battery life or screen size, one decision determines what an ultrasound exam can show: which transducer array touches the patient. The array sets the image shape, how deep the beam reaches, how fine the detail is, and whether the probe can physically get to the target at all. A probe designed for the abdomen cannot produce a useful image of a radial artery, and the reverse is equally true — this is geometry, not marketing.

This guide walks through each main type of ultrasound probe, what its image actually looks like, the frequency and depth it covers, and where it belongs clinically. Every array described here exists in wireless handheld form, so the array choice and the form-factor choice can be made independently.

Catalogue-Vital-Scan-2-4.jpg

The one rule to remember: frequency sets a trade-off, not a quality level. Higher frequency gives finer detail at shallower depth; lower frequency penetrates further with coarser detail. Asking "which frequency is better" is like asking which gear is better on a bicycle.

The Four Core Array Designs

1. Convex (curvilinear) array

Elements sit along a curved face, so the beam fans out into a wide field — wider than the probe's own footprint. On screen this looks like a broad sector, narrow at the top and flaring toward depth.

  • Typical frequency: roughly 1–8 MHz

  • Typical depth: to 300 mm or more

  • Image: wide fan

  • Used for: abdomen (liver, gallbladder, kidneys, aorta), pelvis, obstetric scanning, FAST trauma views, bladder volume

  • Limitation: the curved, larger face needs room; it does not fit between ribs or into small superficial areas

When automatic bladder volume is the entire purpose, the convex principle is taken one step further in a dedicated wireless bladder scanner, which measures volume automatically rather than requiring manual calipers.

四维扫描无线探头式膀胱仪.jpg

2. Linear array

Elements sit in a straight line, sending beams in parallel to produce a rectangular image with no flare. The footprint is flat and wide, which also makes it stable to hold — useful for procedures.

  • Typical frequency: roughly 5–15 MHz

  • Typical depth: 20–100 mm

  • Image: rectangle

  • Used for: vascular access and vein mapping, arterial assessment, thyroid, breast, scrotum, tendons, muscle, nerves, superficial masses, procedural needle guidance

  • Limitation: deliberately shallow; it will not reach abdominal depth

Real spec — SonoStar 8L linear array wireless probe: electronic linear array, 7.5 / 10 MHz, 192 elements with 64 channels, display depth 20 / 40 / 60 / 100 mm adjustable, field of view L40, modes B, B/M, Color, PDI, PW, 256-level gray scale, in-plane and out-of-plane puncture guides with automatic vascular measurement, 2200 mAh battery (1.5 h standard, 3 h with the extended version), 140 × 55 × 20 mm, 180 g, dual-band 2.4G/5G Wi-Fi, iOS / Android / Windows.

3. Phased array

A small cluster of elements pulses with precisely controlled delays, steering and focusing the beam electronically. The result is a sector (pie-shaped) image from a very small contact face — small enough to slide between ribs.

  • Typical frequency: roughly 1–5 MHz

  • Typical depth: 90–240 mm depending on model

  • Image: sector / pie shape

  • Used for: cardiac windows, pericardial fluid, lung (pleural sliding, B-lines), focused abdominal views, procedural guidance through narrow windows

  • Limitation: image quality at very shallow depth is not what a high-frequency linear array delivers

Cardiac work needs velocity estimates, so confirm the model supports colour plus PW and CW spectral Doppler. See the full phased array handheld ultrasound guide for the detailed comparison.

Real spec — SonoStar 6PA: 192 elements / 32 channels, 2.2 / 3.6 MHz, 80° scan angle, depth 90–200 mm, 2600 mAh (~2 h), wireless + USB charging, 135 × 40 × 25 mm, 120 g.
SonoStar 5PA: 128 elements / 32 channels, central 2.8 MHz (cardiac harmonic 3.6 MHz), 80°, depth 90 / 160 / 200 / 240 mm, 15–20 frames/sec, ~1 h, 140 × 35 × 25 mm, 120 g, includes CW Doppler.

4. Endocavity array (transvaginal / transrectal)

A curved or micro-convex array mounted on a slim handle, designed to enter a body cavity. Placing the transducer millimetres from the target allows a much higher frequency than an abdominal scan, so resolution improves dramatically.

  • Typical frequency: roughly 5–8 MHz

  • Typical depth: 30–120 mm

  • Image: wide sector or micro-convex fan

  • Used for: gynaecology and early pregnancy monitoring, pelvic assessment, prostate assessment, follicular monitoring, guidance for oocyte retrieval or prostate biopsy

  • Note: contact with mucous membranes places these probes in the "semi-critical" category — high-level disinfection between patients plus a sterile probe cover is standard practice



8LC-6.jpg

Derivatives Worth Knowing

Micro-convex array

A compromise design: a small curved footprint that still produces a wide field. It reaches places a full-size convex probe cannot — paediatric intercostal windows, small joints, neonatal scanning, small-animal veterinary work — without giving up as much depth as a high-frequency linear array would.

Biplane rectal array

A T-shaped head carries both a convex array and a linear array, giving two perpendicular planes from a single position. Two planes simultaneously means a lesion or needle path can be localised in both axes without moving the probe — which is why the design is used in prostate assessment and anorectal work.

Ultra-high-frequency linear array

Operating in the 16–22 MHz range, this variant trades every millimetre of depth for near-field resolution. It is used for facial aesthetics and vascular mapping, small-part imaging, dermatology, and nerve work where structures sit within a centimetre of the skin.

Ultra-wide linear array

A wider field of view than a standard linear head, at linear-array frequencies. Useful where a larger superficial area needs one pass — chest wall, abdominal wall, extended MSK scanning.

Multi-array probes: 2-in-1, 3-in-1 and interchangeable heads

Rather than carrying separate probes, several arrays can be combined in one housing and switched electronically, or mounted as swappable heads on a shared body.

  • Two-in-one designs typically pair convex + linear, or linear + phased.

  • Three-in-one designs house convex + linear + phased in one unit — see the full 3-in-1 ultrasound probe comparison.

  • Interchangeable-head systems use one body with magnetic hot-swap heads, so the host costs once and the array set grows later.

Real spec — SonoStar three-in-one range (5CPL / 6CPL / 8CPL): convex 3.2 / 5.0 MHz, linear 7.5 / 10.0 MHz, phased 2.5–5.0 MHz depending on model; 128 or 192 elements; 32 channels (5CPL, 6CPL) or 64 channels (8CPL); convex depth to 305 mm, linear to 80 or 100 mm, phased to 160 or 200 mm; in-plane and out-of-plane puncture guides with automatic vascular measurement; 2 h battery with wireless charging; 156 × 60 × 20 mm, 230 g.

Types of Ultrasound Probe: Master Comparison

Probe typeImage shapeFootprintTypical frequencyTypical depthBest for
Convex (curvilinear)Wide fanCurved, medium-large1–8 MHzto 300+ mmAbdomen, pelvis, OB, FAST
LinearRectangleFlat, wide5–15 MHz20–100 mmVascular access, thyroid, breast, MSK, nerves
Phased arraySector (pie)Very small1–5 MHz90–240 mmCardiac, lung, intercostal views
EndocavityWide sectorSlim handle5–8 MHz30–120 mmPelvic / early pregnancy, prostate
Micro-convexCompact fanSmall curved3–8 MHz60–160 mmPaediatric, small joints, vet
Biplane rectalFan + rectangle, perpendicularT-shaped head6–8 MHz40–100 mmProstate, anorectal, biopsy guidance
Ultra-high-frequency linearShallow rectangleSmall-mid linear16–22 MHz10–40 mmAesthetics, superficial vessels, nerves
Multi-array (2-in-1 / 3-in-1)Depends on selected arrayCombinedPer arrayPer arrayGeneralists covering multiple regions

How to Choose: Array First, Everything Else Second

  1. Name the target depth. Under roughly 30 mm → linear or ultra-high-frequency. Roughly 30–120 mm and accessed internally → endocavity or micro-convex. Beyond roughly 90 mm → convex or phased.

  2. Name the access route. Between ribs, subxiphoid, suprasternal → phased array only. Through a body cavity → endocavity. Flat skin surface → linear or convex.

  3. Count the body regions you cover in a day. One region → a dedicated single-array probe gives the best result per dollar. Two or three regions → a combination probe avoids carrying and maintaining three devices.

  4. Check Doppler requirements. Colour Doppler for flow and orientation; PW and CW spectral Doppler whenever velocity or pressure gradients matter — mainly cardiac and some vascular work.

  5. Check needle-guidance features. In-plane and out-of-plane guide lines plus automatic vessel measurement turn a linear or combination probe into an intervention tool.

  6. Then — and only then — optimise form factor. Wireless handheld, cart-based or laptop-style is a workflow question, independent of the array decision.

Common buying mistake: choosing by price or brand and then discovering the array does not fit the exam. A department that mainly cannulates veins will get no return from a deep-penetrating convex probe, however good that probe is. Match array to exam, then compare models within that array.

Specialty Starting Points

Specialty / settingPrimary arrayOften added second
Emergency medicineConvex (FAST, abdominal)Phased (cardiac) + linear (vascular access)
Internal medicine / primary careThree-in-one—
CardiologyPhased array—
Vascular access / anaesthesiaLinearPhased (cardiac assessment before blocks)
OB/GYNConvex (transabdominal)Endocavity (transvaginal)
UrologyBiplane rectalConvex (renal, bladder)
MSK / sports medicine / physiotherapyLinearUltra-high-frequency for small joints and nerves
PaediatricsMicro-convexHigh-frequency linear
Urology workflow with automated PVRConvex bladder scanner—
VeterinaryConvex or micro-convexLinear (rectal transducers for large-animal reproduction)

Department-specific workflows are covered in more depth in SonoStar's Cardiology, Critical Care, Vascular, Anaesthesiology and OB/GYN solution pages, and in the emergency POCUS guide.

Frequently Asked Questions

How many types of ultrasound probes are there?

Four core transducer designs dominate everyday scanning — convex (curvilinear), linear, phased array and endocavity — with derivatives including micro-convex, biplane rectal and multi-array combination probes. Each produces a different image shape and covers a different depth range.

How do I choose an ultrasound probe for a specific exam?

Match the array to the target's depth and access. Deep abdominal or pelvic targets need a convex array. Superficial structures, vessels and MSK need a linear array. Anything requiring a window between the ribs needs a phased array. Anything scanned from inside a body cavity needs an endocavity array.

Does probe frequency affect image quality?

Frequency sets the trade-off between resolution and penetration. Higher frequency gives finer detail at shallower depth; lower frequency penetrates further with coarser detail. Choosing a frequency is choosing where that line falls, not choosing better versus worse.

What is the difference between a phased array and a convex probe?

A phased array has a very small footprint and electronically steered beams producing a sector image, so it fits between the ribs for cardiac views. A convex probe has a curved, larger footprint producing a wide fan from a fixed geometry, optimised for abdominal and pelvic depth.

Why do some probes carry more than one array?

Combination probes put two or three arrays in one housing so a clinician can switch between abdominal, superficial and cardiac imaging without changing devices — fewer units to charge, disinfect and carry. SonoStar's 5CPL, 6CPL and 8CPL each house convex, linear and phased arrays in one body.

Are all of these arrays available as wireless handheld probes?

Yes. Wireless handheld versions exist across the range — convex, linear, high-frequency linear, phased array, micro-convex, endocavity, biplane rectal, two-in-one, three-in-one and interchangeable-head models — each streaming to iOS, Android or Windows devices.

Find the array that fits your exam

Browse SonoStar's single-array, two-in-one and three-in-one wireless probes, or ask for a recommendation based on your case mix.

View the SonoStar Probe Range →

SonoStar (索诺星医疗) manufactures wireless handheld ultrasound probes covering convex, linear, phased array, micro-convex, endocavity, biplane rectal and multi-array configurations. Typical frequency and depth figures describe the general category; exact specifications are taken from the SonoStar product pages linked above. This article is educational and does not constitute medical advice; local credentialing, training, and regulatory requirements apply. Confirm current specifications with SonoStar before purchase.


ADD:Guangzhou, China.  TEL:+86-20-32382095  PHONE:+86 18126862446  EMAIL:sonostar@sonostar.net  WEBSITE:https://www.sonostarmed.com